Problem with a tacho Stoneridge SE5000 - V8

Modified on Tue, 16 Feb, 2021 at 8:39 AM

With the Stoneridge Workshop Tab you need to enter into the CAN parameters on the tachograph and set:
  • Remote downloads: Enabled
  • Remote download C-CAN: Enabled
  • Download visualization: Enabled
  • Remote download card writing: Disabled



If the tachograph is a Stoneridge SE5000-8 REV:02 tachograph and has an aftermarket DSRC module then move the DSRC module from the C-CAN line to the C2-CAN line and reconfigure the tachograph settings.


Aftermarket DSRC cable colorDSRC connection pinConnector AC2-CAN
RED1A1
BLUE2A3
BLACK3A5
GREEN4
C1
YELLOW5
C4