If the Configuration Tool does not recognize the RDU on the USB connector, the unit is probably stuck somewhere in its firmware, or a firmware update failed. The bootloader mode lets you write the firmware again.
Enter the bootloader mode
- Unplug the USB cable from the unit.
- If you have a USB cable with a download button, press the button, keep it pressed and connect the cable to the unit.
- If you do not have such a cable, short the two pins of the black 5x2 pin connector on the side of the unit opposite the LED, next to the board and the USB connector, as in the picture. Connect the USB cable while the short is in place.

Use a USB cable without a hub, and check that the LED of the unit lights.
Check that it worked
Start the Configuration Tool. In the Status Window it shows the bootloader, for example "Bootloader v2.x" and "Type : 0":

Then write the firmware
- The tool does not know the type of the unit in bootloader mode and asks Can't determin device type. Please select from list. Choose the type of your unit. A wrong choice writes the wrong firmware.
- Click the Update tab and then Update Firmware, see Update the firmware and bootloader of an RDU. The bootloader cannot be updated in bootloader mode.
- After the firmware is written, the unit starts normally. Take away the short or the button.
Contact support
If the unit still is not recognized, open a ticket and send the serial number of the unit, the type, the version of the Configuration Tool and what the LED does.